INV=NOT_INVERTED, PULSE=DISABLE_SINGLE_PULSE, EDGE=NO_EDGE_DETECTION, SELECT=CTOUT11_OR_T2_MAT3, SYNCH=DISABLE__SYNCHRONIZ
Timer 3 CAP3_3 capture input multiplexer (GIMA output 15)
INV | Invert input 0 (NOT_INVERTED): Not inverted. 1 (INPUT_INVERTED): Input inverted. |
EDGE | Enable rising edge detection 0 (NO_EDGE_DETECTION): No edge detection. 1 (RISING_EDGE_DETECTIO): Rising edge detection enabled. |
SYNCH | Enable synchronization 0 (DISABLE__SYNCHRONIZ): Disable synchronization. 1 (ENABLE__SYNCHRONIZA): Enable synchronization. |
PULSE | Enable single pulse generation. 0 (DISABLE_SINGLE_PULSE): Disable single pulse generation. 1 (ENABLE_SINGLE_PULSE): Enable single pulse generation. |
SELECT | Select input. Values 0x4 to 0xF are reserved. 0 (CTOUT11_OR_T2_MAT3): CTOUT11 or T2_MAT3 1 (SOF1_START_OF_FRAME): SOF1 (Start-Of-Frame USB1) 2 (T3_CAP3): T3_CAP3 3 (T2_MAT3): T2_MAT3 |
RESERVED | Reserved |